T67XX CO₂ sensor control using Go

The T67XX module is a relatively cheap and easy to use CO₂ sensor that can be used (amongst other methods) over an I²C bus. You can find data on the sensor module on the datasheet

This Go module interfaces with the sensor and allows you configure it, and to read values from it.

Things to note

  • The sensor reaches what it calls "operational accuracy" after 120 seconds, and "full accuracy" after 10 minutes.
  • You probably want to enable ABC calibration on the device.

Both of these things are documented in the code and examples.

Simple usage

package main

import (
	"log"
	"os"
	"time"

	"github.com/wjessop/t67xx"
	"golang.org/x/exp/io/i2c"
)

const (
	// We can change the sensor address on the bus if we want to, but it defaults
	// to 0x21
	t67XXSensorAddress = 0x21
)

func main() {
	// Open an i2c bus that we can pass to the driver
	device, err := i2c.Open(&i2c.Devfs{Dev: "/dev/i2c-1"}, t67XXSensorAddress)
	if err != nil {
		log.Fatalf("Couldn't open the T67XX sensor at %x, error was %v", t67XXSensorAddress, err)
	}

	// Create the driver
	driver := &t67xx.T67XX{}
	driver.Device = device

	// For now the library needs a logger to be provided. It needs to satisfy the
	// following interface:
	//
	// type Logger interface {
	// 	Debug(...interface{})
	// 	Debugf(string, ...interface{})
	// 	Fatalf(string, ...interface{})
	// }
	log := log.New(os.Stderr, "T67XX", log.LstdFlags)
	driver.SetLogger(log)

	// EnableABC enables the ABC calibration. From the datasheet:
	//
	//   "ABC LOGIC™ Automatic Background Logic, or ABC Logic™, is a patented
	//    self-calibration technique that is designed to be used in applications where
	//    concentrations will drop to outside ambient conditions (400 ppm) at least
	//    three times in a 7 days, typically during unoccupied periods. Full accuracy
	//    to be achieved utilizing ABC Logic™. With ABC Logic™ enabled, the sensor will
	//    typically reach its operational accuracy after 24 hours of continuous
	//    operation at a condition that it was exposed to ambient reference levels of
	//    air at 400 ppm CO₂. Sensor will maintain accuracy specifications with ABC
	//    Logic™ enabled, given that it is at least four times in 21 days exposed to
	//    the reference value and this reference value is the lowest concentration
	//    to which the sensor is exposed. ABC Logic™ requires continuous operation of
	//    the sensor for periods of at least 24 hours.
	//
	//    Note: Applies when used in typical residential ambient air. Consult Telaire
	//    if other gases or corrosive agents are part of the application environment."
	if err := driver.EnableABC(); err != nil {
		log.Fatal("Could not enable ABC calibration on the sensor", err)
	}

	// Now we can read the CO₂ readings in a loop, taking care to discard any
	// spurious readings.
	for {
		co2Reading, err := driver.GasPPM()
		if err != nil {
			log.Fatal(err)
		}

		// The sensors I have sometimes give spurious readings. Let's discount them.
		// Adjust these values based on the baseline CO₂ reading you expect. The max is
		// the measurement limit according to the datasheet, but i've seen values well
		// over 10,000.
		if co2Reading > 5000 || co2Reading < 200 {
			log.Printf("Reading of %d from CO₂ sensor was out of allowed bounds", co2Reading)
		} else {
			log.Printf("Got CO₂ reading of %d from CO₂ sensor", co2Reading)
		}

		time.Sleep(10)
	}
}

Waiting until the sensor reaches full accuracy

For my own convenience I added methods to allow for waiting until the sensor has reached full accuracy. They only work in Linux, because that's where I have my sensors attached. They don't really belong in this library, but they're here if you want them. If you object to their presence, or you're not using Linux then you can simply ignore them and do the book keeping yourself.

The methods rely on time since the machine was booted to determine wether the sensor has reached full accuracy yet, assuming that the sensors were plugged in at system boot. From the datasheet:

The sensor is capable of responding to commands after power on, but operational accuracy of sensor won’t happen until 120 sec have elapsed. The sensor will reach full accuracy / warm up after 10 min. of operation.

Using the SleepUntilFullAccuracy() function

The SleepUntilFullAccuracy() function does just that. Based on the time since last system boot it sleeps for the remaining 10 minute duration until the sensor should have reached full accuracy. To avoid blocking your entire program (you may be reading other sensors) you can use a goroutine and channel to signal the rest of the program.

First, create a channel to use as a signal, then in a goroutine close it when the SleepUntilFullAccuracy() function returns:

// Create a signal channel that will be closed when the sensor reaches full accuracy
accuracyChan := make(chan interface{})

go func(driver *t67xx.T67XX) {
	// Sleep in the background until the sensor has been powered up long enough
	// to achieve full accuracy.
	err := driver.SleepUntilFullAccuracy()
	if err != nil {
		log.Fatal("Error sleeping until full accuracy", err)
	}

	// Close the signal channel then exit the goroutine as we no-longer need it.
	close(accuracyChan)
}(driver)

Now, the rest of our program looks similar to the simple example but with a channel select which will only start to succeed if the signal channel is closed:

select {
case <-accuracyChan:
	// A successful read on the closed channel indicates that the sensor is
	// now fully accurate.
	co2Reading, err := driver.GasPPM()
	if err != nil {
		log.Fatal(err)
	}

	// The sensors I have sometimes give spurious readings. Let's discount them.
	// Adjust these values based on the baseline CO₂ reading you expect. The max is
	// the measurement limit according to the datasheet, but i've seen values well
	// over 10,000.
	if co2Reading > 5000 || co2Reading < 200 {
		log.Printf("Reading of %d from CO₂ sensor was out of allowed bounds", co2Reading)
	} else {
		log.Printf("Got CO₂ reading of %d from CO₂ sensor", co2Reading)
	}
default:
	log.Print("Skipping CO₂ reading as the sensor has not yet achieved full accuracy")
}
Using the SensorIsAtFullAccuracy() method

This method simply re-calculates the seconds since system boot each time it is called, and as such is not as efficient for long term/repeated use as the previous method:

accurate, err := driver.SensorIsAtFullAccuracy()
if err != nil {
	log.Fatal("Error sleeping until full accuracy", err)
}

if accurate {
	// do reading
}

Other functions

Changing the address of the sensor on the I²C bus

I used this so I could have 4 sensors all on the same bus so I could check them against each other to check for deviation.

t67XXSensorNewAddress := 0x22 // The sensor defaults to 0x21

if err := driver.SetAddress(byte(t67XXSensorNewAddress)); err != nil {
	log.Fatal(err)
}
Printing the status

The sensor reports some data, mine have only ever reported having the "Calibration error", "I2C" and "Single point calibration" bits set though, so YMMV.

if err := driver.PrintStatus(); err != nil {
	log.Fatal(err)
}

TODO, and things I don't need so won't do but you can

  • Meta methods to determine wether the sensor has reached "operational accuracy".
  • Something useful with the status.
  • Single point calibration triggering and reporting.
  • Firmware. Right now it just returns 1.

License

MIT, see LICENSE.txt

Documentation

Index

Constants

This section is empty.

Variables

This section is empty.

Functions

This section is empty.

Types

type BitValue

type BitValue struct {
	// contains filtered or unexported fields
}

BitValue is a value and a description

type Bitmask

type Bitmask uint16

Bitmask represents a bitmask value

func (Bitmask) IsSet

func (value Bitmask) IsSet(test Bitmask) bool

IsSet returns true if a bit is set

func (Bitmask) ListDescriptions

func (value Bitmask) ListDescriptions(values []BitValue) []string

ListDescriptions returns a string array of all set bits

func (Bitmask) ListValues

func (value Bitmask) ListValues(values []BitValue) []Bitmask

ListValues returns a string array of all set bits

type Logger

type Logger interface {
	Debug(...interface{})
	Debugf(string, ...interface{})
	Fatalf(string, ...interface{})
}

Logger is the definition of the logger interface we need

type T67XX

type T67XX struct {
	Device *i2c.Device
	// contains filtered or unexported fields
}

T67XX encapsulates communications with the T67XX CO₂ sensor

func (*T67XX) EnableABC

func (t *T67XX) EnableABC() error

EnableABC enables the ABC calibration. From the datasheet:

"ABC LOGIC™ Automatic Background Logic, or ABC Logic™, is a patented
 self-calibration technique that is designed to be used in applications where
 concentrations will drop to outside ambient conditions (400 ppm) at least
 three times in a 7 days, typically during unoccupied periods. Full accuracy
 to be achieved utilizing ABC Logic™. With ABC Logic™ enabled, the sensor will
 typically reach its operational accuracy after 24 hours of continuous
 operation at a condition that it was exposed to ambient reference levels of
 air at 400 ppm CO2. Sensor will maintain accuracy specifications with ABC
 Logic™ enabled, given that it is at least four times in 21 days exposed to
 the reference value and this reference value is the lowest concentration
 to which the sensor is exposed. ABC Logic™ requires continuous operation of
 the sensor for periods of at least 24 hours.

 Note: Applies when used in typical residential ambient air. Consult Telaire
 if other gases or corrosive agents are part of the application environment."

func (*T67XX) FirmwareVersion

func (t *T67XX) FirmwareVersion() (int, error)

FirmwareVersion returns the a sensors firmware

func (*T67XX) GasPPM

func (t *T67XX) GasPPM() (int, error)

GasPPM returns the CO₂ parts per million measured on the sensor

func (*T67XX) PrintStatus

func (t *T67XX) PrintStatus() error

PrintStatus prints the status of the sensor

func (*T67XX) Reset

func (t *T67XX) Reset() error

Reset resets the sensor. You will need to make sure the sensor is available before getting a new reading

func (*T67XX) SensorIsAtFullAccuracy

func (t *T67XX) SensorIsAtFullAccuracy() (bool, error)

SensorIsAtFullAccuracy returns true if the sensor has reached it's full accuracy, or false otherwise.

From the datasheet:

"The sensor is capable of responding to commands after power on, but operational
 accuracy of sensor won’t happen until 120 sec have elapsed. The sensor will
 reach full accuracy / warm up after 10 min. of operation."

This code assumed that the sensor was plugged in when the system was booted and hasn't been removed since.

Only works in Linux currently.

func (*T67XX) SetAddress

func (t *T67XX) SetAddress(address byte) error

SetAddress sets the i2c address of the sensor

func (*T67XX) SetLogger

func (t *T67XX) SetLogger(l Logger)

SetLogger sets the logger to use

func (*T67XX) SleepUntilFullAccuracy

func (t *T67XX) SleepUntilFullAccuracy() error

SleepUntilFullAccuracy sleeps for 10 minutes from the time the system was booted, which is the amount of time it takes for the sensor to achieve full accuracy.

If the system was booted more than 10 minutes ago it returns immetiately. Only works on Linux. Not sure if the file is available/works in containers.

This code (and the associated functions it calls) probably aren't really too relevant to the sensor driver itself, they're more her for my convenience.